Currently I am trying to figure out the refresh rate and the mode (such as Avg, or Peek) that the WS‐2813U‐IT La Crossei is set to, it seems to refresh every 15 - 30 seconds or so.
My analog volt meter is nice because is does the "averaging" for you with its slow and steady movements. (mounted in my old IPhone 3 box, saved for some such purpose)
So for a start I decided to assume that the La Crosse was averaging between refresh and so I would mentally average the volts thru that time.
This image shows 6.2 MPH and 16 VDC
The data as collected (with about 50 data points) is Wind Speed x Volts
FYI, I'm going to say that start up speed is about 4 MPH
I crunched the numbers and came up with a TSR of around 5.25, not bad.
Next step is to get a full length jumper cable to bring the Tach on shore and then to call La Crosse and see if I can get a tech to tell me the w/speed mode.
______________________________________________________________________________
07.11.16
Success today!
Yesterday not so much, the couple between the generator and the main shaft cracked as soon as I applied the dummy load. I discovered that I nicked the spring like milling when I drilled it out to receive the main shaft and a week of spinning got it all ready to snap as soon as I applied the load.
This is very good because it shows the weak spots in the design and all of the winter fixes whould be major improvements.
I replaced the couple and all is well for now, I do not expect the new couple to last much longer... we shall see.
With the ammeter spliced in to the system and my dummy load box set to 10 ohms I got a really nice correlation between vdc and amperage, unfortunately the tach is acting very flaky and so now that is harder to get a good number than it should be.
This chart starts to confirm actual output.
07.11.16_________________________________________________________
The new couple lasted about a day but I got some more data from it before it broke.
With new couples and a redesigned main-shaft I will try again in a month.
I have ordered a wired anemometer so that part of the puzzle will be addressed.
I am already planning how to install a bigger stepper generator, I feel that this one will not get me to the 16vdc often enough.
This chart indicates that it should take 12mph to get to 16vdc but I know this data is vague, might be more like 16mph.
I am missing a beautiful 16 - 18 mph day due to the drive train failures so I hope we get some wind in August.
07.17.16______________________________________________________________________
Repaired in one 3 hour session in the shop back at home.
The old couple was hand made (not by me) and both cracked.
Ordered two new ones and installed one with some significant detailed changes to limit the stress on the couple itself.
Experimenting with wind turbines since the 90's I have access to a wonderful open air spot to see anything I make in action. The goal of course has always been to generate power but mostly they have been "decorative" Summer 2016 should show real measurable results for my 3rd generation windmill
Wednesday, July 6, 2016
Sunday, July 3, 2016
HAWT DIY Summer 2016 Test Run
Finally got the system into the water.
Fully tested the Hall effect tachometer and the volt meter connections and all are working fine.
For the wind speed I am using an anemometer from a remote weather system. I have it attached to the tower below the blade; not the best location but for now ,OK.
Maybe I will try and attach it to the housing nose cone but that will throw off the wind direction readings (I don't really need that data.)
Went thru a complete final check of all the fasteners before closing it up for the last time.
Had to create a tool box dedicated to the project.
Created several jumpers for quick connection to the various instruments.
While standing in 2' of water, you need to pay close attention to every move you make and so the on-shore preparations are important.
I have an analog volt meter but it goes only to 30vdc.
Then I have the Tach revised to work out side in brilliant sunlight. A word to the wise, red LED CANNOT be seen in daylight!! I was lucky to have built it into an oversize box and so actually dropped it down into the shadow of the opening and it is fine.
Soon, very soon I will have an assistant aid in the data collection and we will have some numbers regarding the blade design and overall efficiency.
Fully tested the Hall effect tachometer and the volt meter connections and all are working fine.
Maybe I will try and attach it to the housing nose cone but that will throw off the wind direction readings (I don't really need that data.)
Went thru a complete final check of all the fasteners before closing it up for the last time.
Had to create a tool box dedicated to the project.
Created several jumpers for quick connection to the various instruments.
While standing in 2' of water, you need to pay close attention to every move you make and so the on-shore preparations are important.
I have an analog volt meter but it goes only to 30vdc.
Then I have the Tach revised to work out side in brilliant sunlight. A word to the wise, red LED CANNOT be seen in daylight!! I was lucky to have built it into an oversize box and so actually dropped it down into the shadow of the opening and it is fine.
Soon, very soon I will have an assistant aid in the data collection and we will have some numbers regarding the blade design and overall efficiency.